STAINLESSCABLERAILING.COM | 877.560.9545 | 103 CABLE & FITTINGS NOTE: If you are ordering Factory or Swageless Fittings, crimping will not be necessary. STEP 1 Insert cable into the terminal all the way. STEP 3 Turn the knob on the crimper counterclockwise to open the jaws. STEP 5 Turn the knob on the crimper clockwise to close the jaws around the fitting. STEP 7 Repeat the crimping process for a total of three crimps. STEP 6 Pump the handle consecutive times until the two jaw halves nearly touch. WARNING: Only firm handle pressure is needed to close the jaw halves; excessive force may result in damage. STEP 4 Insert and position the cable and fitting into the crimper jaws for crimping. STEP 2 Using the black marker, mark the cable to provide a visual reference that the cable remains fully seated down inside the fitting and does not slip out. How to Swage